← Research
Research paper · Internal technical report, summarised here

Noise in HF RFID installations caused by LED lighting

Sher Bahader

Published in
Technical field study
Date
May 2018

Summary

After installing HF RFID readers in a university library, the readers performed poorly. Measurements showed electrical noise of 300 to 950 mV on every floor with LED lighting, against less than 20 mV with the same reader in areas without it. The cause was electromagnetic interference from low-cost LED drivers that had not been tested against lighting emission standards.

KeywordsHF RFIDElectromagnetic interferenceLED driversEN 55015FCC Part 15Site survey

What happened

HF RFID readers installed in a university library in Madinah were unreliable. Tags were missed and read ranges were short, even though the hardware and configuration were correct.

How it was measured

Noise was measured floor by floor at the reader. Every floor with LED lighting showed between 300 and 950 mV of noise. The same reader, installed in an area without LED lights, measured less than 20 mV and worked normally.

The cause

The interference came from the LED drivers, not the reader. Low-cost drivers are often designed without electromagnetic interference filtering, and these lights had not been tested against lighting emission standards such as EN 55015 in Europe or FCC Part 15 in the US.

What I recommend on every RFID project

  • Measure RF noise at each reader and gate location during the site survey, before hardware is ordered.
  • Ask the electrical contractor for the emission test reports of the lighting, and specify EN 55015 or FCC Part 15 compliant products in the tender.
  • Plan antenna and gate positions away from lighting drivers and power cabling.
  • Agree with the client, in writing, who fixes interference that comes from the building rather than the RFID system.

Read the story behind this study